summaryrefslogtreecommitdiff
path: root/Master/texmf-dist/tex/latex/qcircuit/qcircuit.sty
blob: 1b936386e14e4f9be8ab3cb24e1cc69d48ee8355 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
%    qcircuit version 2.6.0
%    Contributors: Steve Flammia, Bryan Eastin, Travis Scholten
%    This program is free software; you can redistribute it and/or modify
%    it under the terms of the GNU General Public License as published by
%    the Free Software Foundation; either version 2 of the License, or
%    (at your option) any later version.
%
%    This program is distributed in the hope that it will be useful,
%    but WITHOUT ANY WARRANTY; without even the implied warranty of
%    MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See the
%    GNU General Public License for more details.
%
%    You should have received a copy of the GNU General Public License
%    along with this program; if not, write to the Free Software
%    Foundation, Inc., 59 Temple Place, Suite 330, Boston, MA  02111-1307  USA

% Thanks to the Xy-pic guys, Kristoffer H Rose, Ross Moore, and Daniel Müllner,
% for their help in making Qcircuit work with Xy-pic version 3.8.  
% Thanks also to Dave Clader, Andrew Childs, Rafael Possignolo, Tyson Williams,
% Sergio Boixo, Cris Moore, Jonas Anderson, and Stephan Mertens for helping us test 
% and/or develop the new version.
\ProvidesPackage{qcircuit}[2018/08/14]
\RequirePackage{xy}

\DeclareOption{braket}{
    \newcommand{\bra}[1]{\ensuremath{\left\langle{#1}\right\vert}}
    \newcommand{\ket}[1]{\ensuremath{\left\vert{#1}\right\rangle}}
    }

\DeclareOption{qm}{
    \newcommand{\ip}[2]{\ensuremath{\left\langle{#1}\middle\vert{#2}\right\rangle}}
    \newcommand{\melem}[3]{\ensuremath{\left\langle{#1}\middle\vert{#2}\middle\vert{#3}\right\rangle}}
    \newcommand{\expval}[1]{\ensuremath{\left\langle #1 \right\rangle}}
    \newcommand{\op}[2]{\ensuremath{\left\vert{#1}\middle\rangle\middle\langle{#2}\right\vert}}
}

\ProcessOptions\relax

\xyoption{matrix}
\xyoption{frame}
\xyoption{arrow}
\xyoption{arc}

\usepackage{ifpdf}
\ifpdf
\else
\PackageWarningNoLine{Qcircuit}{qcircuit is not loading in PDF mode. Activating all Xy-pic features to compensate. If you wish to use specific drivers for Xy-pic, you must modify the code in qcircuit.sty}
%    The following option loads all the features in Xy-pic. This
%    this is included as work-around to ensure documents compile
%    images correctly when using XeLaTeX.
\xyoption{all}
\fi

% The following resets Xy-pic matrix alignment to the pre-3.8 default, as
% required by Qcircuit.
\entrymodifiers={!C\entrybox}

\newcommand{\qw}[1][-1]{\ar @{-} [0,#1]}
    % Defines a wire that connects horizontally.  By default it connects to the object on the left of the current object.
    % WARNING: Wire commands must appear after the gate in any given entry.
\newcommand{\qwx}[1][-1]{\ar @{-} [#1,0]}
    % Defines a wire that connects vertically.  By default it connects to the object above the current object.
    % WARNING: Wire commands must appear after the gate in any given entry.
\newcommand{\qwa}[1][-1]{\ar @{<-} [0,#1]}
    % Defines a wire that connects horizontally with an arrow.  By default it makes an end wire with an arrow indicating the end of the circuit.
    % WARNING: Wire commands must appear after the gate in any given entry.
\newcommand{\cw}[1][-1]{\ar @{=} [0,#1]}
    % Defines a classical wire that connects horizontally.  By default it connects to the object on the left of the current object.
    % WARNING: Wire commands must appear after the gate in any given entry.
\newcommand{\cwx}[1][-1]{\ar @{=} [#1,0]}
    % Defines a classical wire that connects vertically.  By default it connects to the object above the current object.
    % WARNING: Wire commands must appear after the gate in any given entry.
\newcommand{\cwa}[1][-1]{\ar @{<=} [0,#1]}
    % Defines a classical wire that connects horizontally with an arrow.  By default it makes an end wire with an arrow indicating the end of the circuit.
    % WARNING: Wire commands must appear after the gate in any given entry.
\newcommand{\cds}[2]{*+<1em,.9em>{\hphantom{#2}} \POS [0,0].[#1,0]="e",!C *{#2};"e"+ R \qw}
    % Allows the insertion of text without a box and exands circuit around this text.
    % This is useful for such things as ... to indicate a generalized circuit.
\newcommand{\barrier}[2][-0.95em]{\ar @{--}[#2,1]+<#1, -1em>;[0,1]+<#1, 1em>}
    % Defines a barrier that is represented by a horizontal dashed line.
    % It takes a a single argument to specify how many bits to cover
    % To center the barrier between gates you can adjust the horizontal offset
    % with an optional second parameter. This is the horizontal offset in em.
    % It defaults to -0.95em
    % WARNING: Be sure to place the barrier on the topmost bit it covers, it only propogates downwards
\newcommand{\gate}[1]{*+<.6em>{#1} \POS ="i","i"+UR;"i"+UL **\dir{-};"i"+DL **\dir{-};"i"+DR **\dir{-};"i"+UR **\dir{-},"i" \qw}
    % Boxes the argument, making a gate.
\newcommand{\sgate}[2]{\gate{#1}  \qwx[#2]}
    % Creates a gate and a qwx wire going #2 spots below, for a gate split over
    % non-adjacent rows
\newcommand{\meter}{*=<1.8em,1.4em>{\xy ="j","j"-<.778em,.322em>;{"j"+<.778em,-.322em> \ellipse ur,_{}},"j"-<0em,.4em>;p+<.5em,.9em> **\dir{-},"j"+<2.2em,2.2em>*{},"j"-<2.2em,2.2em>*{} \endxy} \POS ="i","i"+UR;"i"+UL **\dir{-};"i"+DL **\dir{-};"i"+DR **\dir{-};"i"+UR **\dir{-},"i" \qw}
    % Inserts a measurement meter.
    % In case you're wondering, the constants .778em and .322em specify
    % one quarter of a circle with radius 1.1em.
    % The points added at + and - <2.2em,2.2em> are there to strech the
    % canvas, ensuring that the size is unaffected by erratic spacing issues
    % with the arc.
\newcommand{\metersymb}{\xy ="j","j"-<.778em,.322em>;{"j"+<.778em,-.322em> \ellipse ur,_{}},"j"-<0em,.4em>;p+<.5em,.9em> **\dir{-},"j"+<2.2em,2.2em>*{},"j"-<2.2em,2.2em>*{} \endxy}
    % A longer meter
\newcommand{\meterB}[1]{*=<1.8em,2.6em>{\xy 0;<0em,-.8em>:
0*{\begingroup
\everymath{\scriptstyle}
\tiny #1 \endgroup},<0em,.7em>*{\xy ="j","j"-<.778em,-.322em>;{"j"+<.778em,.322em> \ellipse ur,_{}},"j"-<0em,-.2em>;p+<.5em,.9em> **\dir{-},"j"+<2.2em,2.2em>*{},"j"-<2.2em,2.2em>*{} \endxy} 
\endxy} \POS ="i","i"+UR;"i"+UL **\dir{-};"i"+DL **\dir{-};"i"+DR **\dir{-};"i"+UR **\dir{-},"i" \qw}
    % A meter that allows for a measurement operator to be added below
\newcommand{\smeterB}[2]{\meterB{#1} \qwx[#2] \qw}
    % A split meter that allows for a measurement operator to be split over non-
    % adjacent rows
\newcommand{\measure}[1]{*+[F-:<.9em>]{#1} \qw}
    % Inserts a measurement bubble with user defined text.
\newcommand{\measuretab}[1]{*{\xy*+<.6em>{#1}="e";"e"+UL;"e"+UR **\dir{-};"e"+DR **\dir{-};"e"+DL **\dir{-};"e"+LC-<.5em,0em> **\dir{-};"e"+UL **\dir{-} \endxy} \qw}
    % Inserts a measurement tab with user defined text.
\newcommand{\measureD}[1]{*{\xy*+=<0em,.1em>{#1}="e";"e"+UR+<0em,.25em>;"e"+UL+<-.5em,.25em> **\dir{-};"e"+DL+<-.5em,-.25em> **\dir{-};"e"+DR+<0em,-.25em> **\dir{-};{"e"+UR+<0em,.25em>\ellipse^{}};"e"+C:,+(0,1)*{} \endxy} \qw}
    % Inserts a D-shaped measurement gate with user defined text.
\newcommand{\multimeasure}[2]{*+<1em,.9em>{\hphantom{#2}} \qw \POS[0,0].[#1,0];p !C *{#2},p \drop\frm<.9em>{-}}
    % Draws a multiple qubit measurement bubble starting at the current position and spanning #1 additional gates below.
    % #2 gives the label for the gate.
    % You must use an argument of the same width as #2 in \ghost for the wires to connect properly on the lower lines.
\newcommand{\multimeasureD}[2]{*+<1em,.9em>{\hphantom{#2}} \POS [0,0]="i",[0,0].[#1,0]="e",!C *{#2},"e"+UR-<.8em,0em>;"e"+UL **\dir{-};"e"+DL **\dir{-};"e"+DR+<-.8em,0em> **\dir{-};{"e"+DR+<0em,.8em>\ellipse^{}};"e"+UR+<0em,-.8em> **\dir{-};{"e"+UR-<.8em,0em>\ellipse^{}},"i" \qw}
    % Draws a multiple qubit D-shaped measurement gate starting at the current position and spanning #1 additional gates below.
    % #2 gives the label for the gate.
    % You must use an argument of the same width as #2 in \ghost for the wires to connect properly on the lower lines.
\newcommand{\control}{*!<0em,.025em>-=-<.2em>{\bullet}}
    % Inserts an unconnected control.
\newcommand{\controlo}{*+<.01em>{\xy -<.095em>*\xycircle<.19em>{} \endxy}}
    % Inserts a unconnected control-on-0.
\newcommand{\ctrl}[1]{\control \qwx[#1] \qw}
    % Inserts a control and connects it to the object #1 wires below.
\newcommand{\ctrlo}[1]{\controlo \qwx[#1] \qw}
    % Inserts a control-on-0 and connects it to the object #1 wires below.
\newcommand{\cctrl}[1]{\control \cwx[#1] \cw}
    % Inserts a classical control and connects it to the object #1 wires below. 
\newcommand{\cctrlo}[1]{\controlo \cwx[#1] \cw}
    % Inserts a classical control-on-0 and connects it to the object #1 wires below.    
\newcommand{\targ}{*+<.02em,.02em>{\xy ="i","i"-<.39em,0em>;"i"+<.39em,0em> **\dir{-}, "i"-<0em,.39em>;"i"+<0em,.39em> **\dir{-},"i"*\xycircle<.4em>{} \endxy} \qw}
    % Inserts a CNOT target.
\newcommand{\qswap}{*=<0em>{\times} \qw}
    % Inserts half a swap gate.
    % Must be connected to the other swap with \qwx.
\newcommand{\multigate}[2]{*+<1em,.9em>{\hphantom{#2}} \POS [0,0]="i",[0,0].[#1,0]="e",!C *{#2},"e"+UR;"e"+UL **\dir{-};"e"+DL **\dir{-};"e"+DR **\dir{-};"e"+UR **\dir{-},"i" \qw}
    % Draws a multiple qubit gate starting at the current position and spanning #1 additional gates below.
    % #2 gives the label for the gate.
    % You must use an argument of the same width as #2 in \ghost for the wires to connect properly on the lower lines.
\newcommand{\ghost}[1]{*+<1em,.9em>{\hphantom{#1}} \qw}
    % Leaves space for \multigate on wires other than the one on which \multigate appears.  Without this command wires will cross your gate.
    % #1 should match the second argument in the corresponding \multigate.
\newcommand{\cghost}[1]{*+<1em,.9em>{\hphantom{#1}} \cw}
    % Same as ghost but with a classical incoming wire.
\newcommand{\nghost}[1]{*+<1em,.9em>{\hphantom{#1}}}
    % Same as ghost but with no incoming wire.
\newcommand{\push}[1]{*{#1}}
    % Inserts #1, overriding the default that causes entries to have zero size.  This command takes the place of a gate.
    % Like a gate, it must precede any wire commands.
    % \push is useful for forcing columns apart.
    % NOTE: It might be useful to know that a gate is about 1.3 times the height of its contents.  I.e. \gate{M} is 1.3em tall.
    % WARNING: \push must appear before any wire commands and may not appear in an entry with a gate or label.
\newcommand{\gategroup}[6]{\POS"#1,#2"."#3,#2"."#1,#4"."#3,#4"!C*+<#5>\frm{#6}}
    % Constructs a box or bracket enclosing the square block spanning rows #1-#3 and columns=#2-#4.
    % The block is given a margin #5/2, so #5 should be a valid length.
    % #6 can take the following arguments -- or . or _\} or ^\} or \{ or \} or _) or ^) or ( or ) where the first two options yield dashed and
    % dotted boxes respectively, and the last eight options yield bottom, top, left, and right braces of the curly or normal variety.  See the Xy-pic reference manual for more options.
    % \gategroup can appear at the end of any gate entry, but it's good form to pick either the last entry or one of the corner gates.
    % BUG: \gategroup uses the four corner gates to determine the size of the bounding box.  Other gates may stick out of that box.  See \prop.
\newcommand{\inputgroupv}[5]{\POS"#1,1"."#2,1"."#1,1"."#2,1"!C*+<#3>\frm{\{}, \POS"#1,1"."#2,1"."#1,1"."#2,1"*!C!<1.7em,#4>=<0em>{#5}}
    % Constructs an input group with label #5 and a grouping { from rows #1 to #2 with #3 and #4 controlling the spacing
\newcommand{\inputgroup}[4]{\POS"#1,1"."#2,1"."#1,1"."#2,1", \POS"#1,1"."#2,1"."#1,1"."#2,1"*!C!<1em,#3>=<0em>{#4}}
    % Constructs an input group with label #4 from rows #1 to #2 with #3 controlling the spacing
\newcommand{\inputgrouph}[5]{\POS"#1,1"."#2,1"."#1,1"."#2,1", \POS"#1,1"."#2,1"."#1,1"."#2,1"*!C!<#5,#3>=<0em>{#4}}
    % Constructs an input group with label #4 and a grouping /vdots from rows #1 to #2 with #3 and #5 controlling the spacing
\newcommand{\rstick}[1]{*!L!<-.5em,0em>=<0em>{#1}}
    % Centers the left side of #1 in the cell.  Intended for lining up wire labels.  Note that non-gates have default size zero.
\newcommand{\lstick}[1]{*!R!<.5em,0em>=<0em>{#1}}
    % Centers the right side of #1 in the cell.  Intended for lining up wire labels.  Note that non-gates have default size zero.
\newcommand{\ustick}[1]{*!D!<0em,-.5em>=<0em>{#1}}
    % Centers the bottom of #1 in the cell.  Intended for lining up wire labels.  Note that non-gates have default size zero.
\newcommand{\dstick}[1]{*!U!<0em,.5em>=<0em>{#1}}
    % Centers the top of #1 in the cell.  Intended for lining up wire labels.  Note that non-gates have default size zero.
\newcommand{\Qcircuit}{\xymatrix @*=<0em>}
    % Defines \Qcircuit as an \xymatrix with entries of default size 0em.
\newcommand{\link}[2]{\ar @{-} [#1,#2]}
    % Draws a wire or connecting line to the element #1 rows down and #2 columns forward.
\newcommand{\pureghost}[1]{*+<1em,.9em>{\hphantom{#1}}}
    % Same as \ghost except it omits the wire leading to the left. 

\endinput