diff options
Diffstat (limited to 'Master/texmf-dist/source')
-rw-r--r-- | Master/texmf-dist/source/latex/siunitx/siunitx.dtx | 74 |
1 files changed, 46 insertions, 28 deletions
diff --git a/Master/texmf-dist/source/latex/siunitx/siunitx.dtx b/Master/texmf-dist/source/latex/siunitx/siunitx.dtx index f1879925288..489ecfeb58e 100644 --- a/Master/texmf-dist/source/latex/siunitx/siunitx.dtx +++ b/Master/texmf-dist/source/latex/siunitx/siunitx.dtx @@ -222,7 +222,7 @@ dcolumn, rccol and numprint packages. %</driver> % \fi % -%\CheckSum{10141} +%\CheckSum{10144} % % \CharacterTable % {Upper-case \A\B\C\D\E\F\G\H\I\J\K\L\M\N\O\P\Q\R\S\T\U\V\W\X\Y\Z @@ -304,7 +304,8 @@ dcolumn, rccol and numprint packages. % kibi,byte,molar,Molar,mmHg,mebi,torr,parsec,lightyear,clight, % eVperc,addplot,color,milli,cm,Hz,kg,DeclareRobustCommand, % pascal,dalton,addtolocale,DTLnewdb,DTLnewrow,DTLnewdbentry, -% DTLforeach,DTLiffirstrow,DTLmul,newqualifier,hour}} +% DTLforeach,DTLiffirstrow,DTLmul,newqualifier,hour,renewunit, +% degree}} % %\title{\currpkg\ --- A comprehensive (SI) units package^^A % \thanks{This file describes version \fileversion, last revised @@ -2929,6 +2930,19 @@ dcolumn, rccol and numprint packages. % allows the normal use of \pkg{cellspace} with standard column types: % it does \emph{not} work with the \currpkg\ \texttt{S} or \texttt{s} % columns. +% +%\subsection{Using \currpkg\ with the \pkg{mathabx} package} +%\changes{2008/11/26}{v1.1g}{Respect loading of \pkg{mathabx}} +% The \pkg{mathabx} package defines its own \cs{second} and +% \cs{degree} macros. This is respected by \currpkg: if you want the +% \currpkg\ definitions instead, put the lines +%\begin{LaTeXexample}[noexample] +% \makeatletter +% \renewunit{\second}{s} +% \renewunit[valuesep=none]{\degree}{\si@sym@degree} +% \makeatother +%\end{LaTeXexample} +% after |\begin{document}|. % %\iffalse %<*bug> @@ -3339,7 +3353,7 @@ author. % \begin{macrocode} \NeedsTeXFormat{LaTeX2e} \ProvidesPackage{siunitx} - [2008/11/25 v1.1f A comprehensive (SI) units package] + [2008/11/26 v1.1g A comprehensive (SI) units package] % \end{macrocode} % The package requires \eTeX, so the usual test is made. % \begin{macrocode} @@ -10105,7 +10119,7 @@ author. \newunit{\metre}{m} \newunit{\meter}{\metre} \newunit{\mole}{mol} -\newunit{\second}{s} +\AtBeginDocument{\provideunit{\second}{s}} \newunit{\ampere}{A} \newunit{\kelvin}{K} \newunit{\candela}{cd} @@ -10692,7 +10706,7 @@ author. % powers. % \begin{macrocode} \ProvidesFile{si-prefix.cfg} - [2008/11/25 v1.1f siunitx: SI Multiple prefixes] + [2008/11/26 v1.1g siunitx: SI Multiple prefixes] \newprefix{\yocto}{-24}{y} \newprefix{\zepto}{-21}{z} \newprefix{\atto}{-18}{a} @@ -10796,7 +10810,7 @@ author. % is an awkward one, but here the UK standard is used. % \begin{macrocode} \ProvidesFile{si-named.cfg} - [2008/11/25 v1.1f siunitx: SI Named units] + [2008/11/26 v1.1g siunitx: SI Named units] \newunit{\becquerel}{Bq} \newunit{\coulomb}{C} \newunit{\farad}{F} @@ -10892,7 +10906,7 @@ author. % This requires \file{si-prefix.cfg} and \file{si-named.cfg}. % \begin{macrocode} \ProvidesFile{si-prefixed.cfg} - [2008/11/25 v1.1f siunitx: SI Prefixed units] + [2008/11/26 v1.1g siunitx: SI Prefixed units] \requiresiconfigs{prefix,named,accepted,physical} % \end{macrocode} %\begin{macro}{\picometre} @@ -11190,7 +11204,7 @@ author. % block for the appropriate option. First currents. % \begin{macrocode} \ProvidesFile{si-abbr.cfg} - [2008/11/25 v1.1f siunitx: Abbreviated units] + [2008/11/26 v1.1g siunitx: Abbreviated units] \requiresiconfigs{prefix,named,accepted,physical} \newunit{\pA}{\pico\ampere} \newunit{\nA}{\nano\ampere} @@ -11413,7 +11427,7 @@ author. % These are defined here, although some are in very general use. % \begin{macrocode} \ProvidesFile{si-addn.cfg} - [2008/11/25 v1.1f siunitx: SI Additional units] + [2008/11/26 v1.1g siunitx: SI Additional units] \newunit{\angstrom}{\si@sym@ringA} \newunit{\are}{a} \newunit{\hectare}{\hecto\are} @@ -11463,16 +11477,20 @@ author. %\begin{macro}{\percent} % \begin{macrocode} \ProvidesFile{si-accepted.cfg} - [2008/11/25 v1.1f siunitx: SI Accepted units] + [2008/11/26 v1.1g siunitx: SI Accepted units] \newunit{\minute}{min} \newunit{\hour}{h} \newunit{\Day}{d} \newunit{\dday}{d} \ifsi@old@OHM - \newunit[valuesep=none]{\Degree}{\si@sym@degree} + \AtBeginDocument{ + \provideunit[valuesep=none]{\Degree}{\si@sym@degree} + } \else \ifsi@gensymb\else - \provideunit[valuesep=none]{\degree}{\si@sym@degree} + \AtBeginDocument{ + \provideunit[valuesep=none]{\degree}{\si@sym@degree} + } \fi \fi \newunit[valuesep=none]{\arcmin}{\si@sym@minute} @@ -11512,7 +11530,7 @@ author. % for a negative kern does make things a bit complicated. % \begin{macrocode} \ProvidesFile{si-physical.cfg} - [2008/11/25 v1.1f siunitx: SI Physically-measured units] + [2008/11/26 v1.1g siunitx: SI Physically-measured units] \newcommand*{\si@eVspacea}{\text{\kern-\si@eVcorra}}% \newcommand*{\si@eVspaceb}{\text{\kern-\si@eVcorrb}}% \newunit{\electronvolt}{e\protect\si@eVspacea V\protect% @@ -11548,7 +11566,7 @@ author. % own definitions. % \begin{macrocode} \ProvidesFile{si-synchem.cfg} - [2008/11/25 v1.1f siunitx: Units for synthetic chemists] + [2008/11/26 v1.1g siunitx: Units for synthetic chemists] \requiresiconfigs{prefix} \newunit{\mmHg}{mmHg} \newunit{\molar}{\mole\per\cubic\deci\metre} @@ -11569,7 +11587,7 @@ author. % Some units inspired by \pkg{hepunits}. % \begin{macrocode} \ProvidesFile{si-hep.cfg} - [2008/11/25 v1.1f siunitx: Units for high-energy physics] + [2008/11/26 v1.1g siunitx: Units for high-energy physics] \requiresiconfigs{prefix,named} % \end{macrocode} %\begin{macro}{\micron} @@ -11651,7 +11669,7 @@ author. % For astronomy, the \cs{parsec} unit is needed. % \begin{macrocode} \ProvidesFile{si-astro.cfg} - [2008/11/25 v1.1f siunitx: Units for astronomy] + [2008/11/26 v1.1g siunitx: Units for astronomy] \newunit{\parsec}{pc} \newunit{\lightyear}{ly} % \end{macrocode} @@ -11674,7 +11692,7 @@ author. % \SIunits. First, the binary prefixes. % \begin{macrocode} \ProvidesFile{si-binary.cfg} - [2008/11/25 v1.1f siunitx: Binary units] + [2008/11/26 v1.1g siunitx: Binary units] \newprefix[binary]{\kibi}{10}{Ki} \newprefix[binary]{\mebi}{20}{Mi} \newprefix[binary]{\gibi}{30}{Gi} @@ -11717,7 +11735,7 @@ author. % default values.\footnote{The package author is in the UK.} % \begin{macrocode} \ProvidesFile{si-UK.cfg} - [2008/11/25 v1.1f siunitx: UK locale] + [2008/11/26 v1.1g siunitx: UK locale] \sisetup{ unitsep=thin, expproduct=times, @@ -11734,7 +11752,7 @@ author. % The same as for the UK. % \begin{macrocode} \ProvidesFile{si-USA.cfg} - [2008/11/25 v1.1f siunitx: USA locale] + [2008/11/26 v1.1g siunitx: USA locale] \sisetup{ unitsep=thin, expproduct=times, @@ -11751,7 +11769,7 @@ author. % Germany, hopefully. % \begin{macrocode} \ProvidesFile{si-DE.cfg} - [2008/11/25 v1.1f siunitx: Germany locale] + [2008/11/26 v1.1g siunitx: Germany locale] \sisetup{ unitsep=cdot, valuesep=thin, @@ -11768,7 +11786,7 @@ author. % Design decisions taken from the same section of \SIstyle. % \begin{macrocode} \ProvidesFile{si-ZA.cfg} - [2008/11/25 v1.1f siunitx: South Africa locale] + [2008/11/26 v1.1g siunitx: South Africa locale] \sisetup{ unitsep=cdot, valuesep=thin, @@ -11800,7 +11818,7 @@ author. % \units for conflicting options, so users probably expect none. % \begin{macrocode} \ProvidesFile{si-units.cfg} - [2008/11/25 v1.1f siunitx: Emulation of units] + [2008/11/26 v1.1g siunitx: Emulation of units] \si@emulating{units}{1998/08/04 v0.9b} \si@ifloaded{SIunits} {\si@emclash{units}{SIunits}\endinput}{} @@ -11870,7 +11888,7 @@ author. % clash. % \begin{macrocode} \ProvidesFile{si-unitsdef.cfg} - [2008/11/25 v1.1f siunitx: + [2008/11/26 v1.1g siunitx: Emulation of unitsdef] \si@emulating{unitsdef}{2005/01/04 v0.2} \si@ifloaded{SIunits} @@ -12319,7 +12337,7 @@ author. % the macros in \SIstyle as given in the manual for that package. % \begin{macrocode} \ProvidesFile{si-sistyle.cfg} - [2008/11/25 v1.1f siunitx: Emulation of + [2008/11/26 v1.1g siunitx: Emulation of SIstyle] \si@emulating{sistyle}{2006/12/20 v2.3} \sisetup{% @@ -12503,7 +12521,7 @@ author. % \SIunits emulation starts in much the same way. % \begin{macrocode} \ProvidesFile{si-SIunits.cfg} - [2008/11/25 v1.1f siunitx: Emulation of + [2008/11/26 v1.1g siunitx: Emulation of SIunits] \si@emulating{SIunits}{2007/12/02 v1.36} \sisetup{ @@ -13066,7 +13084,7 @@ author. % which are not really to be encouraged. % \begin{macrocode} \ProvidesFile{si-hepunits.cfg} - [2008/11/25 v1.1f siunitx: Emulation of + [2008/11/26 v1.1g siunitx: Emulation of hepunits] \si@emulating{hepunits}{2007/09/27} \requiresiconfigs{SIunits,accepted,prefix,hep} @@ -13221,7 +13239,7 @@ author. % a little emulation and a few macros needed. % \begin{macrocode} \ProvidesFile{si-fancynum.cfg} - [2008/11/25 v1.1f siunitx: Emulation of + [2008/11/26 v1.1g siunitx: Emulation of fancynum] \si@emulating{fancynum}{2000/08/08 0.92} \sisetup{decimalsymbol=cdot,digitsep=comma} @@ -13283,7 +13301,7 @@ author. % test is needed. % \begin{macrocode} \ProvidesFile{si-fancyunits.cfg} - [2008/11/25 v1.1f siunitx: Emulation of + [2008/11/26 v1.1g siunitx: Emulation of fancyunits] \si@emulating{fancyunits}{2007/02/01 v1.0.1} \si@ifloaded{SIunits} |