diff options
Diffstat (limited to 'Master/texmf-dist/source/latex/siunitx/siunitx.dtx')
-rw-r--r-- | Master/texmf-dist/source/latex/siunitx/siunitx.dtx | 52 |
1 files changed, 27 insertions, 25 deletions
diff --git a/Master/texmf-dist/source/latex/siunitx/siunitx.dtx b/Master/texmf-dist/source/latex/siunitx/siunitx.dtx index 0be5011f084..860412b9196 100644 --- a/Master/texmf-dist/source/latex/siunitx/siunitx.dtx +++ b/Master/texmf-dist/source/latex/siunitx/siunitx.dtx @@ -3314,7 +3314,7 @@ author. % \begin{macrocode} \NeedsTeXFormat{LaTeX2e} \ProvidesPackage{siunitx} - [2008/10/13 v1.1b A comprehensive (SI) units package] + [2008/10/22 v1.1c A comprehensive (SI) units package] % \end{macrocode} % The package requires \eTeX, so the usual test is made. % \begin{macrocode} @@ -10645,7 +10645,7 @@ author. % powers. % \begin{macrocode} \ProvidesFile{si-prefix.cfg} - [2008/10/13 v1.1b siunitx: SI Multiple prefixes] + [2008/10/22 v1.1c siunitx: SI Multiple prefixes] \newprefix{\yocto}{-24}{y} \newprefix{\zepto}{-21}{z} \newprefix{\atto}{-18}{a} @@ -10749,7 +10749,7 @@ author. % is an awkward one, but here the UK standard is used. % \begin{macrocode} \ProvidesFile{si-named.cfg} - [2008/10/13 v1.1b siunitx: SI Named units] + [2008/10/22 v1.1c siunitx: SI Named units] \newunit{\becquerel}{Bq} \newunit{\coulomb}{C} \newunit{\farad}{F} @@ -10845,7 +10845,7 @@ author. % This requires \file{si-prefix.cfg} and \file{si-named.cfg}. % \begin{macrocode} \ProvidesFile{si-prefixed.cfg} - [2008/10/13 v1.1b siunitx: SI Prefixed units] + [2008/10/22 v1.1c siunitx: SI Prefixed units] \requiresiconfigs{prefix,named,accepted,physical} % \end{macrocode} %\begin{macro}{\picometre} @@ -11131,7 +11131,7 @@ author. % block for the appropriate option. First currents. % \begin{macrocode} \ProvidesFile{si-abbr.cfg} - [2008/10/13 v1.1b siunitx: Abbreviated units] + [2008/10/22 v1.1c siunitx: Abbreviated units] \requiresiconfigs{prefix,named,accepted,physical} \newunit{\pA}{\pico\ampere} \newunit{\nA}{\nano\ampere} @@ -11339,11 +11339,12 @@ author. %\begin{macro}{\roentgen} %\begin{macro}{\rad} %\begin{macro}{\rem} +%\changes{v1.1c}{2008/10/22}{Uses \cs{provideunit}} % Some units are ``temporarily'' acceptable for use in the SI system. % These are defined here, although some are in very general use. % \begin{macrocode} \ProvidesFile{si-addn.cfg} - [2008/10/13 v1.1b siunitx: SI Additional units] + [2008/10/22 v1.1c siunitx: SI Additional units] \newunit{\angstrom}{\si@sym@ringA} \newunit{\are}{a} \newunit{\hectare}{\hecto\are} @@ -11355,7 +11356,7 @@ author. \newunit{\curie}{Ci} \newunit{\roentgen}{R} \newunit{\rad}{rad} -\newunit{\rem}{rem} +\provideunit{\rem}{rem} % \end{macrocode} %\end{macro} %\end{macro} @@ -11381,6 +11382,7 @@ author. %\begin{macro}{\Day} %\begin{macro}{\dday} %\begin{macro}{\degree} +%\changes{v1.1c}{2008/10/22}{Uses \cs{provideunit}} %\begin{macro}{\Degree} %\begin{macro}{\arcmin} %\begin{macro}{\arcsec} @@ -11392,7 +11394,7 @@ author. %\begin{macro}{\percent} % \begin{macrocode} \ProvidesFile{si-accepted.cfg} - [2008/10/13 v1.1b siunitx: SI Accepted units] + [2008/10/22 v1.1c siunitx: SI Accepted units] \newunit{\minute}{min} \newunit{\hour}{h} \newunit{\Day}{d} @@ -11401,7 +11403,7 @@ author. \newunit[valuesep=none]{\Degree}{\si@sym@degree} \else \ifsi@gensymb\else - \newunit[valuesep=none]{\degree}{\si@sym@degree} + \provideunit[valuesep=none]{\degree}{\si@sym@degree} \fi \fi \newunit[valuesep=none]{\arcmin}{\si@sym@minute} @@ -11441,7 +11443,7 @@ author. % for a negative kern does make things a bit complicated. % \begin{macrocode} \ProvidesFile{si-physical.cfg} - [2008/10/13 v1.1b siunitx: SI Physically-measured units] + [2008/10/22 v1.1c siunitx: SI Physically-measured units] \newcommand*{\si@eVspacea}{\text{\kern-\si@eVcorra}}% \newcommand*{\si@eVspaceb}{\text{\kern-\si@eVcorrb}}% \newunit{\electronvolt}{e\protect\si@eVspacea V\protect% @@ -11477,7 +11479,7 @@ author. % own definitions. % \begin{macrocode} \ProvidesFile{si-synchem.cfg} - [2008/10/13 v1.1b siunitx: Units for synthetic chemists] + [2008/10/22 v1.1c siunitx: Units for synthetic chemists] \requiresiconfigs{prefix} \newunit{\mmHg}{mmHg} \newunit{\molar}{\mole\per\cubic\deci\metre} @@ -11498,7 +11500,7 @@ author. % Some units inspired by \pkg{hepunits}. % \begin{macrocode} \ProvidesFile{si-hep.cfg} - [2008/10/13 v1.1b siunitx: Units for high-energy physics] + [2008/10/22 v1.1c siunitx: Units for high-energy physics] \requiresiconfigs{prefix,named} % \end{macrocode} %\begin{macro}{\micron} @@ -11580,7 +11582,7 @@ author. % For astronomy, the \cs{parsec} unit is needed. % \begin{macrocode} \ProvidesFile{si-astro.cfg} - [2008/10/13 v1.1b siunitx: Units for astronomy] + [2008/10/22 v1.1c siunitx: Units for astronomy] \newunit{\parsec}{pc} \newunit{\lightyear}{ly} % \end{macrocode} @@ -11603,7 +11605,7 @@ author. % \SIunits. First, the binary prefixes. % \begin{macrocode} \ProvidesFile{si-binary.cfg} - [2008/10/13 v1.1b siunitx: Binary units] + [2008/10/22 v1.1c siunitx: Binary units] \newprefix[binary]{\kibi}{10}{Ki} \newprefix[binary]{\mebi}{20}{Mi} \newprefix[binary]{\gibi}{30}{Gi} @@ -11646,7 +11648,7 @@ author. % default values.\footnote{The package author is in the UK.} % \begin{macrocode} \ProvidesFile{si-UK.cfg} - [2008/10/13 v1.1b siunitx: UK locale] + [2008/10/22 v1.1c siunitx: UK locale] \sisetup{ unitsep=thin, expproduct=times, @@ -11663,7 +11665,7 @@ author. % The same as for the UK. % \begin{macrocode} \ProvidesFile{si-USA.cfg} - [2008/10/13 v1.1b siunitx: USA locale] + [2008/10/22 v1.1c siunitx: USA locale] \sisetup{ unitsep=thin, expproduct=times, @@ -11680,7 +11682,7 @@ author. % Germany, hopefully. % \begin{macrocode} \ProvidesFile{si-DE.cfg} - [2008/10/13 v1.1b siunitx: Germany locale] + [2008/10/22 v1.1c siunitx: Germany locale] \sisetup{ unitsep=cdot, valuesep=thin, @@ -11697,7 +11699,7 @@ author. % Design decisions taken from the same section of \SIstyle. % \begin{macrocode} \ProvidesFile{si-ZA.cfg} - [2008/10/13 v1.1b siunitx: South Africa locale] + [2008/10/22 v1.1c siunitx: South Africa locale] \sisetup{ unitsep=cdot, valuesep=thin, @@ -11729,7 +11731,7 @@ author. % \units for conflicting options, so users probably expect none. % \begin{macrocode} \ProvidesFile{si-units.cfg} - [2008/10/13 v1.1b siunitx: Emulation of units] + [2008/10/22 v1.1c siunitx: Emulation of units] \si@emulating{units}{1998/08/04 v0.9b} \si@ifloaded{SIunits} {\si@emclash{units}{SIunits}\endinput}{} @@ -11799,7 +11801,7 @@ author. % clash. % \begin{macrocode} \ProvidesFile{si-unitsdef.cfg} - [2008/10/13 v1.1b siunitx: + [2008/10/22 v1.1c siunitx: Emulation of unitsdef] \si@emulating{unitsdef}{2005/01/04 v0.2} \si@ifloaded{SIunits} @@ -12248,7 +12250,7 @@ author. % the macros in \SIstyle as given in the manual for that package. % \begin{macrocode} \ProvidesFile{si-sistyle.cfg} - [2008/10/13 v1.1b siunitx: Emulation of + [2008/10/22 v1.1c siunitx: Emulation of SIstyle] \si@emulating{sistyle}{2006/12/20 v2.3} \sisetup{% @@ -12432,7 +12434,7 @@ author. % \SIunits emulation starts in much the same way. % \begin{macrocode} \ProvidesFile{si-SIunits.cfg} - [2008/10/13 v1.1b siunitx: Emulation of + [2008/10/22 v1.1c siunitx: Emulation of SIunits] \si@emulating{SIunits}{2007/12/02 v1.36} \sisetup{ @@ -12995,7 +12997,7 @@ author. % which are not really to be encouraged. % \begin{macrocode} \ProvidesFile{si-hepunits.cfg} - [2008/10/13 v1.1b siunitx: Emulation of + [2008/10/22 v1.1c siunitx: Emulation of hepunits] \si@emulating{hepunits}{2007/09/27} \requiresiconfigs{SIunits,accepted,prefix,hep} @@ -13150,7 +13152,7 @@ author. % a little emulation and a few macros needed. % \begin{macrocode} \ProvidesFile{si-fancynum.cfg} - [2008/10/13 v1.1b siunitx: Emulation of + [2008/10/22 v1.1c siunitx: Emulation of fancynum] \si@emulating{fancynum}{2000/08/08 0.92} \sisetup{decimalsymbol=cdot,digitsep=comma} @@ -13212,7 +13214,7 @@ author. % test is needed. % \begin{macrocode} \ProvidesFile{si-fancyunits.cfg} - [2008/10/13 v1.1b siunitx: Emulation of + [2008/10/22 v1.1c siunitx: Emulation of fancyunits] \si@emulating{fancyunits}{2007/02/01 v1.0.1} \si@ifloaded{SIunits} |