summaryrefslogtreecommitdiff
path: root/Master/texmf-dist/source/latex/siunitx
diff options
context:
space:
mode:
authorKarl Berry <karl@freefriends.org>2009-03-28 00:28:43 +0000
committerKarl Berry <karl@freefriends.org>2009-03-28 00:28:43 +0000
commit7f2abf2484994dd940cb6f108a2998f9f7e12807 (patch)
treebd8477eaf9d1236014662548c7f09b03f14584a2 /Master/texmf-dist/source/latex/siunitx
parentfdcf555ea5d583b5ae1696740ab787dc7a3014c1 (diff)
siunitx update (24mar09)
git-svn-id: svn://tug.org/texlive/trunk@12541 c570f23f-e606-0410-a88d-b1316a301751
Diffstat (limited to 'Master/texmf-dist/source/latex/siunitx')
-rw-r--r--Master/texmf-dist/source/latex/siunitx/siunitx.dtx62
1 files changed, 32 insertions, 30 deletions
diff --git a/Master/texmf-dist/source/latex/siunitx/siunitx.dtx b/Master/texmf-dist/source/latex/siunitx/siunitx.dtx
index a1f8fb52b9d..38be72a6c9a 100644
--- a/Master/texmf-dist/source/latex/siunitx/siunitx.dtx
+++ b/Master/texmf-dist/source/latex/siunitx/siunitx.dtx
@@ -1033,7 +1033,7 @@ dcolumn, rccol and numprint packages.
%\end{table}
%\begin{table}
% \caption{The derived SI units with defined names
-% (\opt{load=derived})}
+% (\opt{load=named})}
% \label{tab:derived}
% \centering
% \begin{tabular}{llllll}
@@ -3431,7 +3431,7 @@ author.
% \begin{macrocode}
\NeedsTeXFormat{LaTeX2e}
\ProvidesPackage{siunitx}
- [2009/02/20 v1.2f A comprehensive (SI) units package]
+ [2009/03/23 v1.2g A comprehensive (SI) units package]
% \end{macrocode}
% The package requires \eTeX, so the usual test is made.
% \begin{macrocode}
@@ -4018,6 +4018,8 @@ author.
loading package}}
% \end{macrocode}
%\end{macro}
+%\changes{2009/03/23}{v1.2g}{Added missing \texttt{space} option
+% for various separators}
%\begin{macro}{\si@unitsep}
%\begin{macro}{\si@unitspace}
%\begin{macro}{\si@errspace}
@@ -4031,14 +4033,14 @@ author.
% \opt{valuesep}.} other entries will be treated as custom spaces.
% \begin{macrocode}
\si@opt@xchoicekey{unitsep}
- {thin,med,medium,thick,none,comma,stop,fullstop,period,
+ {space,thin,med,medium,thick,none,comma,stop,fullstop,period,
times,tighttimes,cdot,tightcdot}{thin}
\si@opt@xchoicekey{unitspace}{space,thin,med,medium,thick,
none}{thin}
\si@opt@xchoicekey{errspace}{space,thin,med,medium,thick,
none}{none}
\si@opt@xchoicekey{valuesep}
- {thin,med,medium,thick,none,comma,stop,fullstop,period,
+ {space,thin,med,medium,thick,none,comma,stop,fullstop,period,
times,tighttimes,cdot,tightcdot}{thin}
% \end{macrocode}
%\end{macro}
@@ -4053,7 +4055,7 @@ author.
% \opt{digitsep=none} will be used for no separation at all.
% \begin{macrocode}
\si@opt@xchoicekey{digitsep}
- {thin,med,medium,thick,none,comma,stop,fullstop,period,
+ {space,thin,med,medium,thick,none,comma,stop,fullstop,period,
times,tighttimes,cdot,tightcdot}{thin}
% \end{macrocode}
%\end{macro}
@@ -4071,7 +4073,7 @@ author.
% seconds, when using \cs{ang}.
% \begin{macrocode}
\si@opt@xchoicekey{anglesep}
- {thin,med,medium,thick,none,comma,stop,fullstop,period,
+ {space,thin,med,medium,thick,none,comma,stop,fullstop,period,
times,tighttimes,cdot,tightcdot}{none}
% \end{macrocode}
%\end{macro}
@@ -10894,7 +10896,7 @@ author.
% powers.
% \begin{macrocode}
\ProvidesFile{si-prefix.cfg}
- [2009/02/20 v1.2f siunitx: SI Multiple prefixes]
+ [2009/03/23 v1.2g siunitx: SI Multiple prefixes]
\newprefix{\yocto}{-24}{y}
\newprefix{\zepto}{-21}{z}
\newprefix{\atto}{-18}{a}
@@ -10998,7 +11000,7 @@ author.
% is an awkward one, but here the UK standard is used.
% \begin{macrocode}
\ProvidesFile{si-named.cfg}
- [2009/02/20 v1.2f siunitx: SI Named units]
+ [2009/03/23 v1.2g siunitx: SI Named units]
\newunit{\becquerel}{Bq}
\newunit{\coulomb}{C}
\newunit{\farad}{F}
@@ -11094,7 +11096,7 @@ author.
% This requires \file{si-prefix.cfg} and \file{si-named.cfg}.
% \begin{macrocode}
\ProvidesFile{si-prefixed.cfg}
- [2009/02/20 v1.2f siunitx: SI Prefixed units]
+ [2009/03/23 v1.2g siunitx: SI Prefixed units]
\requiresiconfigs{prefix,named,accepted,physical}
% \end{macrocode}
%\begin{macro}{\picometre}
@@ -11392,7 +11394,7 @@ author.
% block for the appropriate option. First currents.
% \begin{macrocode}
\ProvidesFile{si-abbr.cfg}
- [2009/02/20 v1.2f siunitx: Abbreviated units]
+ [2009/03/23 v1.2g siunitx: Abbreviated units]
\requiresiconfigs{prefix,named,accepted,physical}
\newunit{\pA}{\pico\ampere}
\newunit{\nA}{\nano\ampere}
@@ -11615,7 +11617,7 @@ author.
% These are defined here, although some are in very general use.
% \begin{macrocode}
\ProvidesFile{si-addn.cfg}
- [2009/02/20 v1.2f siunitx: SI Additional units]
+ [2009/03/23 v1.2g siunitx: SI Additional units]
\newunit{\angstrom}{\si@sym@ringA}
\newunit{\are}{a}
\newunit{\hectare}{\hecto\are}
@@ -11664,7 +11666,7 @@ author.
%\begin{macro}{\bel}
% \begin{macrocode}
\ProvidesFile{si-accepted.cfg}
- [2009/02/20 v1.2f siunitx: SI Accepted units]
+ [2009/03/23 v1.2g siunitx: SI Accepted units]
\newunit{\minute}{min}
\newunit{\hour}{h}
\newunit{\Day}{d}
@@ -11722,7 +11724,7 @@ author.
% for a negative kern does make things a bit complicated.
% \begin{macrocode}
\ProvidesFile{si-physical.cfg}
- [2009/02/20 v1.2f siunitx: SI Physically-measured units]
+ [2009/03/23 v1.2g siunitx: SI Physically-measured units]
\newcommand*{\si@eVspacea}{\text{\kern-\si@eVcorra}}%
\newcommand*{\si@eVspaceb}{\text{\kern-\si@eVcorrb}}%
\newunit{\electronvolt}{e\protect\si@eVspacea V\protect%
@@ -11758,7 +11760,7 @@ author.
% own definitions.
% \begin{macrocode}
\ProvidesFile{si-synchem.cfg}
- [2009/02/20 v1.2f siunitx: Units for synthetic chemists]
+ [2009/03/23 v1.2g siunitx: Units for synthetic chemists]
\requiresiconfigs{prefix}
\newunit{\mmHg}{mmHg}
\newunit{\molar}{\mole\per\cubic\deci\metre}
@@ -11779,7 +11781,7 @@ author.
% Some units inspired by \pkg{hepunits}.
% \begin{macrocode}
\ProvidesFile{si-hep.cfg}
- [2009/02/20 v1.2f siunitx: Units for high-energy physics]
+ [2009/03/23 v1.2g siunitx: Units for high-energy physics]
\requiresiconfigs{prefix,named}
% \end{macrocode}
%\begin{macro}{\micron}
@@ -11861,7 +11863,7 @@ author.
% For astronomy, the \cs{parsec} unit is needed.
% \begin{macrocode}
\ProvidesFile{si-astro.cfg}
- [2009/02/20 v1.2f siunitx: Units for astronomy]
+ [2009/03/23 v1.2g siunitx: Units for astronomy]
\newunit{\parsec}{pc}
\newunit{\lightyear}{ly}
% \end{macrocode}
@@ -11876,7 +11878,7 @@ author.
% The unit \cs{gon} is useful here.
% \begin{macrocode}
\ProvidesFile{si-geophys.cfg}
- [2009/02/20 v1.2f siunitx: Units for astronomy]
+ [2009/03/23 v1.2g siunitx: Units for astronomy]
\newunit{\gon}{gon}
% \end{macrocode}
%\end{macro}
@@ -11891,7 +11893,7 @@ author.
% For astronomy, the \cs{parsec} unit is needed.
% \begin{macrocode}
\ProvidesFile{si-chemeng.cfg}
- [2009/02/20 v1.2f siunitx: Units for chemical engineering]
+ [2009/03/23 v1.2g siunitx: Units for chemical engineering]
\newunit{\gmol}{g\text{-}mol}
\newunit{\kgmol}{kg\text{-}mol}
\newunit{\lbmol}{lb\text{-}mol}
@@ -11916,7 +11918,7 @@ author.
% \SIunits. First, the binary prefixes.
% \begin{macrocode}
\ProvidesFile{si-binary.cfg}
- [2009/02/20 v1.2f siunitx: Binary units]
+ [2009/03/23 v1.2g siunitx: Binary units]
\newprefix[binary]{\kibi}{10}{Ki}
\newprefix[binary]{\mebi}{20}{Mi}
\newprefix[binary]{\gibi}{30}{Gi}
@@ -11959,7 +11961,7 @@ author.
% default values.\footnote{The package author is in the UK.}
% \begin{macrocode}
\ProvidesFile{si-UK.cfg}
- [2009/02/20 v1.2f siunitx: UK locale]
+ [2009/03/23 v1.2g siunitx: UK locale]
\sisetup{
unitsep=thin,
expproduct=times,
@@ -11976,7 +11978,7 @@ author.
% The same as for the UK.
% \begin{macrocode}
\ProvidesFile{si-USA.cfg}
- [2009/02/20 v1.2f siunitx: USA locale]
+ [2009/03/23 v1.2g siunitx: USA locale]
\sisetup{
unitsep=thin,
expproduct=times,
@@ -11993,7 +11995,7 @@ author.
% Germany, hopefully.
% \begin{macrocode}
\ProvidesFile{si-DE.cfg}
- [2009/02/20 v1.2f siunitx: Germany locale]
+ [2009/03/23 v1.2g siunitx: Germany locale]
\sisetup{
unitsep=cdot,
valuesep=thin,
@@ -12011,7 +12013,7 @@ author.
% Design decisions taken from the same section of \SIstyle.
% \begin{macrocode}
\ProvidesFile{si-ZA.cfg}
- [2009/02/20 v1.2f siunitx: South Africa locale]
+ [2009/03/23 v1.2g siunitx: South Africa locale]
\sisetup{
unitsep=cdot,
valuesep=thin,
@@ -12043,7 +12045,7 @@ author.
% \units for conflicting options, so users probably expect none.
% \begin{macrocode}
\ProvidesFile{si-units.cfg}
- [2009/02/20 v1.2f siunitx: Emulation of units]
+ [2009/03/23 v1.2g siunitx: Emulation of units]
\si@emulating{units}{1998/08/04 v0.9b}
\si@ifloaded{SIunits}
{\si@emclash{units}{SIunits}\endinput}{}
@@ -12113,7 +12115,7 @@ author.
% clash.
% \begin{macrocode}
\ProvidesFile{si-unitsdef.cfg}
- [2009/02/20 v1.2f siunitx:
+ [2009/03/23 v1.2g siunitx:
Emulation of unitsdef]
\si@emulating{unitsdef}{2005/01/04 v0.2}
\si@ifloaded{SIunits}
@@ -12562,7 +12564,7 @@ author.
% the macros in \SIstyle as given in the manual for that package.
% \begin{macrocode}
\ProvidesFile{si-sistyle.cfg}
- [2009/02/20 v1.2f siunitx: Emulation of
+ [2009/03/23 v1.2g siunitx: Emulation of
SIstyle]
\si@emulating{sistyle}{2006/12/20 v2.3}
\sisetup{%
@@ -12746,7 +12748,7 @@ author.
% \SIunits emulation starts in much the same way.
% \begin{macrocode}
\ProvidesFile{si-SIunits.cfg}
- [2009/02/20 v1.2f siunitx: Emulation of
+ [2009/03/23 v1.2g siunitx: Emulation of
SIunits]
\si@emulating{SIunits}{2007/12/02 v1.36}
\sisetup{
@@ -13309,7 +13311,7 @@ author.
% which are not really to be encouraged.
% \begin{macrocode}
\ProvidesFile{si-hepunits.cfg}
- [2009/02/20 v1.2f siunitx: Emulation of
+ [2009/03/23 v1.2g siunitx: Emulation of
hepunits]
\si@emulating{hepunits}{2007/09/27}
\requiresiconfigs{SIunits,accepted,prefix,hep}
@@ -13464,7 +13466,7 @@ author.
% a little emulation and a few macros needed.
% \begin{macrocode}
\ProvidesFile{si-fancynum.cfg}
- [2009/02/20 v1.2f siunitx: Emulation of
+ [2009/03/23 v1.2g siunitx: Emulation of
fancynum]
\si@emulating{fancynum}{2000/08/08 0.92}
\sisetup{decimalsymbol=cdot,digitsep=comma}
@@ -13526,7 +13528,7 @@ author.
% test is needed.
% \begin{macrocode}
\ProvidesFile{si-fancyunits.cfg}
- [2009/02/20 v1.2f siunitx: Emulation of
+ [2009/03/23 v1.2g siunitx: Emulation of
fancyunits]
\si@emulating{fancyunits}{2007/02/01 v1.0.1}
\si@ifloaded{SIunits}