diff options
author | Karl Berry <karl@freefriends.org> | 2009-12-16 00:54:56 +0000 |
---|---|---|
committer | Karl Berry <karl@freefriends.org> | 2009-12-16 00:54:56 +0000 |
commit | 496dffd6b86ed4b777ee2bce534ae2063580ed95 (patch) | |
tree | ce6057a1d0d31b6d93a7a730a8a8073e41ee679e /Master/texmf-dist/source/latex/siunitx | |
parent | 266ba94198bf87cad9d0e5618c09f1ceac410c97 (diff) |
siunitx update (15dec09)
git-svn-id: svn://tug.org/texlive/trunk@16419 c570f23f-e606-0410-a88d-b1316a301751
Diffstat (limited to 'Master/texmf-dist/source/latex/siunitx')
-rw-r--r-- | Master/texmf-dist/source/latex/siunitx/siunitx.dtx | 63 |
1 files changed, 31 insertions, 32 deletions
diff --git a/Master/texmf-dist/source/latex/siunitx/siunitx.dtx b/Master/texmf-dist/source/latex/siunitx/siunitx.dtx index fd91d28abe5..f9f3107f7c2 100644 --- a/Master/texmf-dist/source/latex/siunitx/siunitx.dtx +++ b/Master/texmf-dist/source/latex/siunitx/siunitx.dtx @@ -143,7 +143,7 @@ This work consists of the file siunitx.dtx \documentclass[german,english,UKenglish]{ltxdoc} \EnableCrossrefs \CodelineIndex -\RecordChanges +\RecordChanges \usepackage[final]{graphicx} \IfFileExists{xfrac.sty}{\usepackage{xfrac}}{} \usepackage{jawltxdoc} @@ -1330,7 +1330,7 @@ This work consists of the file siunitx.dtx % \SI{106.42}{\dalton} %\end{LaTeXexample} % -%\subsection{High-energy physics (\opt{hep})} +%\subsection{High-energy physics (\opt{h})} % In contrast to \pkg{hepunits}, \currpkg does not define a long list % of compound units for high-energy physics.\footnote{Using the % \opt{emulate=hepunits} option will load a file defining those.} @@ -3261,9 +3261,9 @@ author. % \caption{Good and bad columns} % \label{tab:exp} % \sisetup{tabnumalign=centre} -% \begin{tabular}{% -% c% -% S[tabformat=1.3e1]<{\,\si{\kilogram}}% +% \begin{tabular}{ +% c +% S[tabformat=1.3e1]<{{\,\si{\kilogram}}} % S[tabformat=2.2]} % \toprule % Entry & \multicolumn{1}{c}{Mass} & @@ -3322,7 +3322,7 @@ author. % \begin{macrocode} \NeedsTeXFormat{LaTeX2e} \ProvidesPackage{siunitx} - [2009/10/24 v1.3d A comprehensive (SI) units package] + [2009/12/15 v1.3e A comprehensive (SI) units package] % \end{macrocode} % The package requires \eTeX, so the usual test is made. % \begin{macrocode} @@ -7646,7 +7646,7 @@ author. \ifsi@ang@toarc \expandafter\si@ang@dectoarc \else - \sisetup{padangle=none}\expandafter\si@ang@typeset + \sisetup{padangle=none,anglesep=none}\expandafter\si@ang@typeset \fi} \newcommand*{\si@ang@arc}{% \let\si@ang@fix\si@ang@arcfix @@ -10827,7 +10827,7 @@ author. % powers. % \begin{macrocode} \ProvidesFile{si-prefix.cfg} - [2009/10/24 v1.3d siunitx: SI Multiple prefixes] + [2009/12/15 v1.3e siunitx: SI Multiple prefixes] \newprefix{\yocto}{-24}{y} \newprefix{\zepto}{-21}{z} \newprefix{\atto}{-18}{a} @@ -10931,7 +10931,7 @@ author. % is an awkward one, but here the UK standard is used. % \begin{macrocode} \ProvidesFile{si-named.cfg} - [2009/10/24 v1.3d siunitx: SI Named units] + [2009/12/15 v1.3e siunitx: SI Named units] \newunit{\becquerel}{Bq} \newunit{\coulomb}{C} \newunit{\farad}{F} @@ -11030,7 +11030,7 @@ author. % This requires \file{si-prefix.cfg} and \file{si-named.cfg}. % \begin{macrocode} \ProvidesFile{si-prefixed.cfg} - [2009/10/24 v1.3d siunitx: SI Prefixed units] + [2009/12/15 v1.3e siunitx: SI Prefixed units] \requiresiconfigs{prefix,named,accepted,physical} % \end{macrocode} %\begin{macro}{\picometre} @@ -11328,7 +11328,7 @@ author. % block for the appropriate option. First currents. % \begin{macrocode} \ProvidesFile{si-abbr.cfg} - [2009/10/24 v1.3d siunitx: Abbreviated units] + [2009/12/15 v1.3e siunitx: Abbreviated units] \requiresiconfigs{prefix,named,accepted,physical} \newunit{\pA}{\pico\ampere} \newunit{\nA}{\nano\ampere} @@ -11551,7 +11551,7 @@ author. % These are defined here, although some are in very general use. % \begin{macrocode} \ProvidesFile{si-addn.cfg} - [2009/10/24 v1.3d siunitx: SI Additional units] + [2009/12/15 v1.3e siunitx: SI Additional units] \provideunit{\angstrom}{\si@sym@ringA} \AtBeginDocument{% \ifdefined\Saveangstrom @@ -11606,7 +11606,7 @@ author. %\begin{macro}{\bel} % \begin{macrocode} \ProvidesFile{si-accepted.cfg} - [2009/10/24 v1.3d siunitx: SI Accepted units] + [2009/12/15 v1.3e siunitx: SI Accepted units] \newunit{\minute}{min} \newunit{\hour}{h} \newunit{\Day}{d} @@ -11664,7 +11664,7 @@ author. % for a negative kern does make things a bit complicated. % \begin{macrocode} \ProvidesFile{si-physical.cfg} - [2009/10/24 v1.3d siunitx: SI Physically-measured units] + [2009/12/15 v1.3e siunitx: SI Physically-measured units] \newcommand*{\si@eVspacea}{\text{\kern-\si@eVcorra}}% \newcommand*{\si@eVspaceb}{\text{\kern-\si@eVcorrb}}% \newunit{\electronvolt}{e\protect\si@eVspacea V\protect% @@ -11700,7 +11700,7 @@ author. % own definitions. % \begin{macrocode} \ProvidesFile{si-synchem.cfg} - [2009/10/24 v1.3d siunitx: Units for synthetic chemists] + [2009/12/15 v1.3e siunitx: Units for synthetic chemists] \requiresiconfigs{prefix} \newunit{\mmHg}{mmHg} \newunit{\molar}{\mole\per\cubic\deci\metre} @@ -11721,7 +11721,7 @@ author. % Some units inspired by \pkg{hepunits}. % \begin{macrocode} \ProvidesFile{si-hep.cfg} - [2009/10/24 v1.3d siunitx: Units for high-energy physics] + [2009/12/15 v1.3e siunitx: Units for high-energy physics] \requiresiconfigs{prefix,named} % \end{macrocode} %\begin{macro}{\micron} @@ -11803,7 +11803,7 @@ author. % For astronomy, the \cs{parsec} unit is needed. % \begin{macrocode} \ProvidesFile{si-astro.cfg} - [2009/10/24 v1.3d siunitx: Units for astronomy] + [2009/12/15 v1.3e siunitx: Units for astronomy] \newunit{\parsec}{pc} \newunit{\lightyear}{ly} % \end{macrocode} @@ -11818,7 +11818,7 @@ author. % The unit \cs{gon} is useful here. % \begin{macrocode} \ProvidesFile{si-geophys.cfg} - [2009/10/24 v1.3d siunitx: Units for astronomy] + [2009/12/15 v1.3e siunitx: Units for astronomy] \newunit{\gon}{gon} % \end{macrocode} %\end{macro} @@ -11833,7 +11833,7 @@ author. % For astronomy, the \cs{parsec} unit is needed. % \begin{macrocode} \ProvidesFile{si-chemeng.cfg} - [2009/10/24 v1.3d siunitx: Units for chemical engineering] + [2009/12/15 v1.3e siunitx: Units for chemical engineering] \newunit{\gmol}{g\text{-}mol} \newunit{\kgmol}{kg\text{-}mol} \newunit{\lbmol}{lb\text{-}mol} @@ -11858,7 +11858,7 @@ author. % \SIunits. First, the binary prefixes. % \begin{macrocode} \ProvidesFile{si-binary.cfg} - [2009/10/24 v1.3d siunitx: Binary units] + [2009/12/15 v1.3e siunitx: Binary units] \newprefix[binary]{\kibi}{10}{Ki} \newprefix[binary]{\mebi}{20}{Mi} \newprefix[binary]{\gibi}{30}{Gi} @@ -11901,7 +11901,7 @@ author. % default values.\footnote{The package author is in the UK.} % \begin{macrocode} \ProvidesFile{si-UK.cfg} - [2009/10/24 v1.3d siunitx: UK locale] + [2009/12/15 v1.3e siunitx: UK locale] \sisetup{ unitsep=thin, expproduct=times, @@ -11919,7 +11919,7 @@ author. % The same as for the UK. % \begin{macrocode} \ProvidesFile{si-USA.cfg} - [2009/10/24 v1.3d siunitx: USA locale] + [2009/12/15 v1.3e siunitx: USA locale] \sisetup{ unitsep=thin, expproduct=times, @@ -11937,7 +11937,7 @@ author. % Germany, hopefully. % \begin{macrocode} \ProvidesFile{si-DE.cfg} - [2009/10/24 v1.3d siunitx: Germany locale] + [2009/12/15 v1.3e siunitx: Germany locale] \sisetup{ unitsep=cdot, valuesep=thin, @@ -11955,7 +11955,7 @@ author. % Design decisions taken from the same section of \SIstyle. % \begin{macrocode} \ProvidesFile{si-ZA.cfg} - [2009/10/24 v1.3d siunitx: South Africa locale] + [2009/12/15 v1.3e siunitx: South Africa locale] \sisetup{ unitsep=cdot, valuesep=thin, @@ -11988,7 +11988,7 @@ author. % \units for conflicting options, so users probably expect none. % \begin{macrocode} \ProvidesFile{si-units.cfg} - [2009/10/24 v1.3d siunitx: Emulation of units] + [2009/12/15 v1.3e siunitx: Emulation of units] \si@emulating{units}{1998/08/04 v0.9b} \si@ifloaded{SIunits} {\si@emclash{units}{SIunits}\endinput}{} @@ -12058,7 +12058,7 @@ author. % clash. % \begin{macrocode} \ProvidesFile{si-unitsdef.cfg} - [2009/10/24 v1.3d siunitx: + [2009/12/15 v1.3e siunitx: Emulation of unitsdef] \si@emulating{unitsdef}{2005/01/04 v0.2} \si@ifloaded{SIunits} @@ -12507,7 +12507,7 @@ author. % the macros in \SIstyle as given in the manual for that package. % \begin{macrocode} \ProvidesFile{si-sistyle.cfg} - [2009/10/24 v1.3d siunitx: Emulation of + [2009/12/15 v1.3e siunitx: Emulation of SIstyle] \si@emulating{sistyle}{2006/12/20 v2.3} \sisetup{% @@ -12691,7 +12691,7 @@ author. % \SIunits emulation starts in much the same way. % \begin{macrocode} \ProvidesFile{si-SIunits.cfg} - [2009/10/24 v1.3d siunitx: Emulation of + [2009/12/15 v1.3e siunitx: Emulation of SIunits] \si@emulating{SIunits}{2007/12/02 v1.36} \sisetup{ @@ -13250,7 +13250,7 @@ author. % which are not really to be encouraged. % \begin{macrocode} \ProvidesFile{si-hepunits.cfg} - [2009/10/24 v1.3d siunitx: Emulation of + [2009/12/15 v1.3e siunitx: Emulation of hepunits] \si@emulating{hepunits}{2007/09/27} \requiresiconfigs{SIunits,accepted,prefix,hep} @@ -13405,7 +13405,7 @@ author. % a little emulation and a few macros needed. % \begin{macrocode} \ProvidesFile{si-fancynum.cfg} - [2009/10/24 v1.3d siunitx: Emulation of + [2009/12/15 v1.3e siunitx: Emulation of fancynum] \si@emulating{fancynum}{2000/08/08 0.92} \sisetup{decimalsymbol=cdot,digitsep=comma} @@ -13467,7 +13467,7 @@ author. % test is needed. % \begin{macrocode} \ProvidesFile{si-fancyunits.cfg} - [2009/10/24 v1.3d siunitx: Emulation of + [2009/12/15 v1.3e siunitx: Emulation of fancyunits] \si@emulating{fancyunits}{2007/02/01 v1.0.1} \si@ifloaded{SIunits} @@ -13666,7 +13666,6 @@ author. \usepackage{lmodern} \usepackage[final]{listings,graphicx,microtype} \usepackage[scaled=0.95]{helvet} -\usepackage[version=3]{mhchem} \usepackage[osf]{mathpazo} \usepackage{booktabs,array,url,courier,xspace,varioref} \usepackage{upgreek,ifpdf,float,caption,longtable,babel} |