summaryrefslogtreecommitdiff
path: root/Master/texmf-dist/doc/man
diff options
context:
space:
mode:
Diffstat (limited to 'Master/texmf-dist/doc/man')
-rw-r--r--Master/texmf-dist/doc/man/man1/fixmsxpart.1185
-rw-r--r--Master/texmf-dist/doc/man/man1/fixmsxpart.man1.pdfbin8984 -> 0 bytes
-rw-r--r--Master/texmf-dist/doc/man/man1/msxlint.man1.pdfbin4197 -> 16579 bytes
3 files changed, 0 insertions, 185 deletions
diff --git a/Master/texmf-dist/doc/man/man1/fixmsxpart.1 b/Master/texmf-dist/doc/man/man1/fixmsxpart.1
deleted file mode 100644
index 2a546fcea3d..00000000000
--- a/Master/texmf-dist/doc/man/man1/fixmsxpart.1
+++ /dev/null
@@ -1,185 +0,0 @@
-.\" This manpage is licensed under the GNU Public License
-.TH FIXMSXPART 1 2015-02-05 "" ""
-
-.SH NAME
-fixmsxpart \- corrects note spacing in a single-staff MusiXTeX part
-
-.SH SYNOPSIS
-.B fixmsxpart
-.RB [ \-v\ |\ \-\-version\ |\ \-h\ |\ \-\-help ]
-
-.B fixmsxpart
-.RB [ \-d\ | \ \-\-debug ]
-.IR infile [ \fB.tex\fB ]
-.RI [ outfile [ \fB.tex\fP ]]
-
-
-Converts a single-staff MusiXTeX part (possibly derived from a multi-instrument score and as a result having irregular note spacing) to a single-staff part with proper spacing determined by the notes themselves.
-
-If
-.IR outfile
-is not specifed, standard output is used.
-
-.SH USAGE
-
-.SS Generating a Single-Instrument Part
-
-To generate a single-instrument part from (a copy of) the MusiXTeX source for
-a multi-instrument score, add
-.nf
-
- \\input musixtnt
-
-.fi
-to the preamble,
-set
-.nf
-
- \\instrumentnumber1
-
-.fi
-and use the \\TransformNotes macro defined in musixtnt.tex to discard all but one part.
-For example, the following line placed
-after
-\\startpiece (but before any note commands) would be appropriate for
-a
-.IR four -instrument
-score (arguments #2, #3, #4, and #5, separated by three &s),
-and will result in a part for the
-.IR second
-of these (#3):
-
-.nf
- \\TransformNotes{#2&#3&#4&#5}{#3}
-.fi
-
-Argument #1 is a scaling
-parameter and should not be modified.
-.B
-It is essential that every \\znotes, \\notes, \\Notes, \\NOtes, etc. command in the score match the macro pattern exactly;
-insufficient (or too many) note segments
-will result in lost text and possibly compilation failure; see
-.BR msxlint (1).
-It is assumed by \\TransformNotes that notes commands are terminated by \\en (rather than \\enotes).
-
-Some additional manual changes to the source will be necessary:
-.TP 3
-+
-adjustments of \\setname1, \\setclef1, \\setsign1 , \\setmeter1 and \\setstaffs1 commands, as necessary;
-.TP 3
-+
-ensuring that tempo and roadmap markings
-.RB ( D.C. ,
-.BR Fine ,
-etc.) are in the
-appropriate instrument segment;
-.PP
-Finally, if the modified score is compiled and viewed, it may be seen that horizontal
-spacing designed for
-.I multiple
-instruments often produces bad
-spacing for a
-.IR single
-instrument.
-This can be corrected manually (and very tediously) but it is
-what
-.B fixmsxpart
-was designed to fix (much more conveniently).
-
-.SS Correcting Horizontal Spacing Using fixmsxpart
-The
-\\notes \\Notes \\NOtes \\NOTes...
-commands in a
-part derived from a multi-instrument score are unreliable,
-and so
-.B fixmsxpart
-determines the spacing for ordinary notes by the note
-commands themselves; for example,
-.TP 3
-+
-\\qa, \\qu, \\ql, \\qp result in
-\\NOtes;
-.TP 3
-+
-\\ca, \\cu, \\cl, \\ds result in \\Notes;
-.PP
-and so on.
-Spacing commands \\sk and \\hsk in the input are
-discarded (but \\qsk, \\hqsk and explicit uses of \\off{...} are preserved).
-
-.B fixmsxpart
-determines the spacing for
-.IR beamed
-notes by the beam
-multiplicity: \\ib... results in \\Notes, \\ibb... results in
-\\notes, etc. Some beam-termination commands (\\tb...) are
-problematic because the immediately-following beam note
-\\qb... must be spaced according to the spacing
-.IR before
-the \\tb... command. This is handled by setting a
-variable
-.IR new_beaming
-when processing the \\tb... command
-and only updating
-.IR beaming
-to
-.IR new_beaming
-when processing
-the subsequent beam note. This isn't needed for the
-abbreviations \\tqb, \\tqh, \\ztqb and \\ztqh which combine beam-termination and
-specification of the
-final beam note.
-
-.IR Pointed
-notes are
-.IR not
-given extra space
-automatically. They should be given extra space manually
-in the score
-by using either a \\roff-like command on the subsequent
-note or the \\qsk or \\hqsk spacing commands.
-
-Additional features of
-.BR fixmsxpart
-transformation:
-.TP 3
-+
-Successive whole-bar rests are
-accumulated into a multi-bar rest, with appropriate adjustment of the bar number.
-.TP 3
-+
-\\alaligne
-and \\alapage commands are replaced by \\bar.
-.TP 3
-+
-\\mulooseness, \\eject, \\linegoal, \\song{top | bottom}, \\group{top | bottom}
-and \\akkoladen
-commands are commented out.
-.TP 3
-+
-\\instrumentnumber... commands become
-\\instrumentnumber1.
-.TP 3
-+
-\\nostartrule is added to
-the preamble.
-.TP 3
-+
-Simple slurs or ties initiated by \\slur or \\tie are normalized by
-setting the
-.IR n
-parameter to 1 on the
-assumption that the new note spacing is correct.
-
-.SH LIMITATIONS
-Only single-staff instrumental parts are supported. User-defined macros are not expanded.
-A few esoteric MusiXTeX commands
-and constructions are not supported.
-
-.SH SEE ALSO
-.BR msxlint (1)
-.PP
-musixdoc.pdf
-
-.SH AUTHOR
-This program and manual page were written by Bob Tennent <rdt@cs.queensu.ca>.
diff --git a/Master/texmf-dist/doc/man/man1/fixmsxpart.man1.pdf b/Master/texmf-dist/doc/man/man1/fixmsxpart.man1.pdf
deleted file mode 100644
index b259c22a813..00000000000
--- a/Master/texmf-dist/doc/man/man1/fixmsxpart.man1.pdf
+++ /dev/null
Binary files differ
diff --git a/Master/texmf-dist/doc/man/man1/msxlint.man1.pdf b/Master/texmf-dist/doc/man/man1/msxlint.man1.pdf
index 0707ad7f9e6..ff468a54488 100644
--- a/Master/texmf-dist/doc/man/man1/msxlint.man1.pdf
+++ b/Master/texmf-dist/doc/man/man1/msxlint.man1.pdf
Binary files differ